TROPIC-AMPLIFIER-MIB DEFINITIONS ::= BEGIN

-- (c) Copyright 2023 Nokia Networks.  All rights reserved.
-- This software is the confidential and proprietary property of
-- Nokia and may only be used in accordance with the terms of the
-- license agreement provided with this software.

IMPORTS
      SnmpAdminString                         FROM SNMP-FRAMEWORK-MIB
      OBJECT-TYPE, MODULE-IDENTITY,
      Unsigned32, Integer32                   FROM SNMPv2-SMI
      MODULE-COMPLIANCE, OBJECT-GROUP         FROM SNMPv2-CONF
      TruthValue                              FROM SNMPv2-TC
      ifIndex, InterfaceIndexOrZero           FROM IF-MIB
      tnShelfIndex                            FROM TROPIC-SHELF-MIB
      tnSlotIndex                             FROM TROPIC-SLOT-MIB
      TnCommand,
      NokiaAmpPortTargetPowerWidth            FROM TROPIC-TC
      tnCardModules, tnAmplifierMIB           FROM TROPIC-GLOBAL-REG;

  tnAmplifierMibModule MODULE-IDENTITY
      LAST-UPDATED    "202302101200Z"
      ORGANIZATION    "Nokia"
      CONTACT-INFO    "Nokia
                       Attn: Jeff Donnelly
                       600 Mountain Avenue
                       New Providence, NJ 07974

                       Phone: +1 732 221 6408
                       Email: jeff.donnelly@nokia.com"

      DESCRIPTION "Amplifier MIB types."

      REVISION    "202302101200Z"
      DESCRIPTION "Added the following to tnAmplifierCardInfoTable:
                   tnAmplifierCardOAM1LPumpTemperatures
                   tnAmplifierCardOAM2LPumpTemperatures
                   tnAmplifierCardOAM3LPumpTemperatures
                   tnAmplifierCardOAM1LPumpBiases
                   tnAmplifierCardOAM2LPumpBiases
                   tnAmplifierCardOAM3LPumpBiases."

      REVISION    "202212091200Z"
      DESCRIPTION "Added the following to tnAmplifierCardConfigTable:
                   tnAmplifierCardOptIntAson."

      REVISION    "202209021200Z"
      DESCRIPTION "Added the following to tnAmplifierCardConfigTable:
                   tnAmplifierCardAsonAddDropPlannedForOpsLBand."

      REVISION    "202205131200Z"
      DESCRIPTION "Added the following to tnAmplifierCardConfigTable:
                   tnAmplifierCardUsage."

      REVISION    "202107231200Z"
      DESCRIPTION "Added the following to tnAmplifierPortInfoTable:
                   tnAmplifierPortAprEDFApulsePower."

      REVISION    "202106041200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortAsellLinkL."

      REVISION    "202012181200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortTargetPowerWidth
                   tnAmplifierPortTargetPowerWidthL."

      REVISION    "202011061200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortAsellLink."

      REVISION    "202010301200Z"
      DESCRIPTION "1) Added the following to tnAmplifierPortConfigTable:
                      tnAmplifierPortSpanLossTh.
                   2) Added the following to tnAmplifierPortInfoTable:
                      tnAmplifierPortSpanLoss."

      REVISION    "202003061200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortAPREDFAPulseAttempt."

      REVISION    "202002141200Z"
      DESCRIPTION "Added the following to tnAmplifierPortOperatingMode:
                   maxPower(3)."

      REVISION    "202001311200Z"
      DESCRIPTION "Added the following to tnAmplifierPortOperatingModeL:
                   maxPower(3)."

      REVISION    "202001171200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortLineDcmConnAddress."

      REVISION    "201810101200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortAprEDFApulse."

      REVISION    "201805181200Z"
      DESCRIPTION "Added the following to tnAmplifierPortInfoTable:
                   tnAmplifierPortPowerOutL."

      REVISION    "201803301200Z"
      DESCRIPTION "1) Added the following to tnAmplifierPortConfigTable:
                      tnAmplifierPortBoosterTargetPowerIn.
                   2) Added the following to tnAmplifierPortInfoTable:
                      tnAmplifierPortInfoOSCRxPowerIn
                      tnAmplifierPortInfoOSCSfpTxPowerOut
                      tnAmplifierPortInfoOSCSfpRxPowerIn
                      tnAmplifierPortBoosterTargetPowerOut.
                   3) Added the following to tnAmplifierCardInfoTable:
                      tnAmplifierCardOAM3PumpTemperatures
                      tnAmplifierCardOAM3PumpBiases."

      REVISION    "201802231200Z"
      DESCRIPTION "Updated the contact info."

      REVISION    "201802091200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortLosModeL."

      REVISION    "201709291200Z"
      DESCRIPTION "1) Added the following to tnAmplifierPortConfigTable:
                      tnAmplifierPortBandMode.
                   2) Added the following to tnAmplifierPortInfoTable:
                      tnAmplifierPortPowerInL."

      REVISION    "201709221200Z"
      DESCRIPTION "Removed the range of the following in tnAmplifierPortInfoTable:
                   tnAmplifierActOutAtten
                   tnAmplifierActOutAttenL."

      REVISION    "201707071200Z"
      DESCRIPTION "Fixed MIB compile issues."

      REVISION    "201706231200Z"
      DESCRIPTION "Added the following to tnAmplifierCardInfoTable:
                   tnAmplifierCardOAM1PumpTemperatures
                   tnAmplifierCardOAM2PumpTemperatures
                   tnAmplifierCardOAM1PumpBiases
                   tnAmplifierCardOAM2PumpBiases."

      REVISION    "201705311200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortOperatingModeL
                   tnAmplifierPortSignalPowerTargetL
                   tnAmplifierPortUserSelectedExteriorDcmPresentIn
                   tnAmplifierPortUserSelectedExteriorDcmPresentOut."

      REVISION    "201702241200Z"
      DESCRIPTION "1) Added the following to tnAmplifierPortConfigTable:
                      tnAmplifierPortGainTiltL
                      tnAmplifierPortPowerGainBackoffL
                      tnAmplifierPortPowerSpanRepairMarginL.
                   2) Added the following to tnAmplifierPortInfoTable:
                      tnAmplifierPortActualTiltL
                      tnAmplifierPortSignalPowerOutL
                      tnAmplifierPortInputToOutputGainL
                      tnAmplifierPortOSCTxPowerOutL."

      REVISION    "201611161200Z"
      DESCRIPTION "Updated the contact info."

      REVISION    "201611111200Z"
      DESCRIPTION "Added the following to tnAmplifierPortInfoTable:
                   tnAmplifierCommonEgressOutputPowerL,
                   tnAmplifierActOutAttenL."

      REVISION    "201610131200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortPowerGainL
                   tnAmplifierPortPowerGainMinL
                   tnAmplifierPortPowerGainMaxL
                   tnAmplifierPortPowerDeltaMaxL
                   tnAmplifierPortGainRangeL
                   tnAmplifierPortTargetTiltL
                   tnAmplifierPortVoaSetL."

      REVISION    "201605311200Z"
      DESCRIPTION "Added the following to tnAmplifierCardInfoTable:
                   tnAmplifierCardOAMLPump[1-4]Temperature,
                   tnAmplifierCardOAMLPump[1-4]Bias."

      REVISION    "201605211200Z"
      DESCRIPTION "Added the following to tnAmplifierPortInfoTable:
                   tnAmplifierCommonEgressOutputPower,
                   tnAmplifierActOutAtten."

      REVISION    "201407311200Z"
      DESCRIPTION "Changed the syntax of tnAmplifierPortSignalPowerTarget
                   to Integer32 from Unsigned32."

      REVISION    "201406121200Z"
      DESCRIPTION "1) Added the following to tnAmplifierPortConfigTable:
                      tnAmplifierPortOperatingMode
                      tnAmplifierPortSignalPowerTarget.
                   2) Added the following to tnAmplifierPortInfoTable:
                      tnAmplifierPortTestingActive."

      REVISION    "201403181200Z"
      DESCRIPTION "Added the following to tnAmplifierHybridCardInfoTable:
                   tnAmplifierHybridCardOAMPump[3-4]Temperature
                   tnAmplifierHybridCardOAMPump[3-4]Bias."

      REVISION    "201403111200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortGainRange
                   tnAmplifierPortAprMode."

      REVISION    "201402261200Z"
      DESCRIPTION "Added ranges and DEFVAL to attributes."

      REVISION    "201309051200Z"
      DESCRIPTION "Added the following to tnAmplifierCardConfigTable:
                   tnAmplifierCardAsonAddDropPlannedForOps."

      REVISION    "201305231200Z"
      DESCRIPTION "1) Updated ranges and defaults for the following:
                      tnAmplifierPortPowerSpanRepairMargin.
                   2) Updated defaults for the following:
                      tnAmplifierPortGainTilt
                      tnAmplifierPortPowerOut."

      REVISION    "201305131200Z"
      DESCRIPTION "1) Added the following to tnAmplifierPortInfoTable:
                      tnAmplifierPortOSCTxPowerIn
                      tnAmplifierPortOSCTxPowerOut.
                   2) Marked the following as obsolete:
                      tnAmplifierObjs
                      tnAmplifierEvents."

      REVISION    "201303161200Z"
      DESCRIPTION "Added the following to tnAmplifierCardInfoTable:
                   tnAmplifierCardOAMPump[4-6]Temperature
                   tnAmplifierCardOAMPump[4-6]Bias."

      REVISION    "201211261200Z"
      DESCRIPTION "Added the following to tnAmplifierPortInfoTable:
                   tnAmplifierPortWtOcmMonitorPortOut."

      REVISION    "201209271200Z"
      DESCRIPTION "Added the following DEFVAL for tnAmplifierPortAprHoldOffTime:
                   time0ms."

      REVISION    "201207161200Z"
      DESCRIPTION "Added the following tables:
                   tnAmplifierHybridPortConfigTable
                   tnAmplifierHybridPortInfoTable
                   tnAmplifierHybridCardInfoTable."

      REVISION    "201106151200Z"
      DESCRIPTION "1) Changed range for tnAmplifierMeshCardCommonEgressPower
                      from (-3000, 1100) to (-1000, 1000), and the default
                      from 0 to 100.
                   2) Added DEFVAL for the following attributes:
                      tnAmplifierMeshPortPowerOut, -9900
                      tnAmplifierMeshPortSignalPowerOut, -9900."

      REVISION    "201105231200Z"
      DESCRIPTION "Added DEFVAL for the following attributes:
                   tnAmplifierPortPowerDeltaMax, 0
                   tnAmplifierPortDCMInPower, -9900
                   tnAmplifierPortDCMOutPower, -9900."

      REVISION    "201104281200Z"
      DESCRIPTION "Added the following tables:
                   tnAmplifierMeshPortInfoTable
                   tnAmplifierMeshCardConfigTable
                   tnAmplifierMeshCardInfoTable."

      REVISION    "201103071200Z"
      DESCRIPTION "Updated range to (0,9900) and added default of
                   9900 for tnAmplifierCardOptIntSpanLoss."

      REVISION    "201011161200Z"
      DESCRIPTION "1) Added the following to tnAmplifierCardInfoTable:
                      tnAmplifierCardOptIntSpanLoss
                   2) Added the following to a new MIB table,
                      tnAmplifierCardConfigTable:
                      tnAmplifierCardOptIntDetection
                      tnAmplifierCardOptIntBaseline
                      tnAmplifierCardOptIntLossThreshold
                      tnAmplifierCardOptIntPollPeriod
                      tnAmplifierCardOptIntClearAlarm."

      REVISION    "201010311200Z"
      DESCRIPTION "Added ranges for AM2125A and AM2318A to the following:
                   tnAmplifierPortPowerGain
                   tnAmplifierPortPowerGainMin
                   tnAmplifierPortPowerGainMax."

      REVISION    "201010241200Z"
      DESCRIPTION "1) Added the following to tnAmplifierPortConfigTable:
                      tnAmplifierPortVoaSet.
                   2) Added the following to tnAmplifierPortInfoTable:
                      tnAmplifierPortInputToOutputGain
                      tnAmplifierPortDCMInPower
                      tnAmplifierPortDCMOutPower
                      tnAmplifierPortActualTilt."

      REVISION    "201010181200Z"
      DESCRIPTION "Marked the following as obsolete:
                   tnAmplifierPortAutoReEnableBackoffTime."

      REVISION    "201010141200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortSignalFailThreshold
                   tnAmplifierPortSignalDegradeThreshold."

      REVISION    "201009101200Z"
      DESCRIPTION "1) Marked the following in tnAmplifierPortAprHoldOffTime
                      as obsolete:
                      time50ms(2)
                      time100ms(3).
                   2) Added the following to tnAmplifierPortAprHoldOffTime:
                      time250ms(4)."

      REVISION    "201008151200Z"
      DESCRIPTION "Changed losa(1) to auto(1) for tnAmplifierPortLosMode."

      REVISION    "201007291200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortAprHoldOffTime
                   tnAmplifierPortLosMode."

      REVISION    "201007051200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortGainTilt."

      REVISION    "201006161200Z"
      DESCRIPTION "Added the following to tnAmplifierPortConfigTable:
                   tnAmplifierPortSRSTiltACoeffDCM
                   tnAmplifierPortMaxFlatGainOffset."

      REVISION    "201006041200Z"
      DESCRIPTION "Added ranges for AM2017B and AM2325B to the following:
                   tnAmplifierPortPowerGain
                   tnAmplifierPortPowerGainMin
                   tnAmplifierPortPowerGainMax."

      REVISION    "201002251200Z"
      DESCRIPTION "Updated range for tnAmplifierPortPowerDeltaMax from
                   (0, 9999) to (0, 500)."

      REVISION    "201002171200Z"
      DESCRIPTION "Added range for ALPFGT to the following:
                   tnAmplifierPortPowerGain,
                   tnAmplifierPortPowerGainMin
                   tnAmplifierPortPowerGainMax."

      REVISION    "201002091200Z"
      DESCRIPTION "Updated range for A2325A to the following:
                   tnAmplifierPortPowerGain,
                   tnAmplifierPortPowerGainMin
                   tnAmplifierPortPowerGainMax."

      REVISION    "201001241200Z"
      DESCRIPTION "1) Added the following MIB table:
                      tnAmplifierCardInfo.
                   2) Added the following to tnAmplifierCardInfoTable:
                      tnAmplifierCardOAMPump[1-3]Temperature
                      tnAmplifierCardOAMPump[1-3]Bias.
                   3) Added range for A2325A to the following:
                      tnAmplifierPortPowerGain
                      tnAmplifierPortPowerGainMin
                      tnAmplifierPortPowerGainMax."

      REVISION    "200912111200Z"
      DESCRIPTION "Added tnAmplifierPortAprDisable."

      REVISION    "200912031200Z"
      DESCRIPTION "Added range for ALPFGK to the following:
                   tnAmplifierPortPowerGain
                   tnAmplifierPortPowerGainMin
                   tnAmplifierPortPowerGainMax."

      REVISION    "200903181200Z"
      DESCRIPTION "Added range for AHPLG to the following:
                   tnAmplifierPortPowerGain,
                   tnAmplifierPortPowerGainMin
                   tnAmplifierPortPowerGainMax."

      REVISION    "200811171200Z"
      DESCRIPTION "Changed range of tnAmplifierPortTargetTilt to (-300, 0)."

      REVISION    "200810161200Z"
      DESCRIPTION "Marked the following as deprecated:
                   tnAmplifierPortAutoReEnableBackoffTime."

      REVISION    "200805221200Z"
      DESCRIPTION "tnAmplifierPortPowerGainBackoff will not be obsoleted."

      REVISION    "200804111200Z"
      DESCRIPTION "1) Updated the amplifier gain attribute ranges to
                      AHPHG: 1300 to 3300 and ALPHG: 1000 to 3000.
                   2) Removed:
                      tnAmplifierPortDeviationIn
                      tnAmplifierPortDeviationOut."

      REVISION    "200803281200Z"
      DESCRIPTION "Updated the amplifier gain attribute ranges."

      REVISION    "200802161200Z"
      DESCRIPTION "1) Changed the attribute descriptions to include
                      1830 card types.
                   2) Added comments to attributes that will be obsoleted.
                   3) Added the following MIB attributes:
                      tnAmplifierPortPowerDeltaMax
                      tnAmplifierPortDeviationIn
                      tnAmplifierPortDeviationOut
                      tnAmplifierPortTargetTilt
                      tnAmplifierPortFunction."

      ::= { tnCardModules 4 }

  tnAmplifierConf                      OBJECT IDENTIFIER ::= { tnAmplifierMIB 1 }
  tnAmplifierGroups                    OBJECT IDENTIFIER ::= { tnAmplifierConf 1 }
  tnAmplifierPortConfigGroups          OBJECT IDENTIFIER ::= { tnAmplifierGroups 1 }
  tnAmplifierPortInfoGroups            OBJECT IDENTIFIER ::= { tnAmplifierGroups 2 }
  tnAmplifierCardInfoGroups            OBJECT IDENTIFIER ::= { tnAmplifierGroups 3 }
  tnAmplifierCardConfigGroups          OBJECT IDENTIFIER ::= { tnAmplifierGroups 4 }
  tnAmplifierCompliances               OBJECT IDENTIFIER ::= { tnAmplifierConf 2 }
  tnAmplifierPortConfigCompliances     OBJECT IDENTIFIER ::= { tnAmplifierCompliances 1 }
  tnAmplifierPortInfoCompliances       OBJECT IDENTIFIER ::= { tnAmplifierCompliances 2 }
  tnAmplifierCardInfoCompliances       OBJECT IDENTIFIER ::= { tnAmplifierCompliances 3 }
  tnAmplifierCardConfigCompliances     OBJECT IDENTIFIER ::= { tnAmplifierCompliances 4 }
--  obsolete
--  tnAmplifierObjs                      OBJECT IDENTIFIER ::= { tnAmplifierMIB 2 }
--  tnAmplifierEvents                    OBJECT IDENTIFIER ::= { tnAmplifierMIB 3 }
  tnAmplifierPortConfig                OBJECT IDENTIFIER ::= { tnAmplifierMIB 4 }
  tnAmplifierPortInfo                  OBJECT IDENTIFIER ::= { tnAmplifierMIB 5 }
  tnAmplifierCardInfo                  OBJECT IDENTIFIER ::= { tnAmplifierMIB 6 }
  tnAmplifierCardConfig                OBJECT IDENTIFIER ::= { tnAmplifierMIB 7 }

--------------------------------------------------------------------------------
-- Type Definitions
--------------------------------------------------------------------------------

--------------------------------------------------------------------------------
-- Amplifier Port Config Scalars
--------------------------------------------------------------------------------
    tnAmplifierPortConfigAttributeTotal OBJECT-TYPE
        SYNTAX         Integer32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Total number of attributes in
                        tnAmplifierPortConfigTable."
        ::= { tnAmplifierPortConfig 1 }

--------------------------------------------------------------------------------
-- Amplifier Port Config Table
--------------------------------------------------------------------------------
    tnAmplifierPortConfigTable OBJECT-TYPE
        SYNTAX         SEQUENCE OF TnAmplifierPortConfigEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "The provisioned ports on an amplifier card."
        ::= { tnAmplifierPortConfig 2 }

    tnAmplifierPortConfigEntry OBJECT-TYPE
        SYNTAX         TnAmplifierPortConfigEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "."
        INDEX { ifIndex }
        ::= { tnAmplifierPortConfigTable 1 }

    TnAmplifierPortConfigEntry ::= SEQUENCE {
        tnAmplifierPortPowerGain                          Unsigned32,
        tnAmplifierPortPowerGainMin                       Unsigned32,
        tnAmplifierPortPowerGainMax                       Unsigned32,
        tnAmplifierPortPowerGainBackoff                   Unsigned32,
        tnAmplifierPortEnable                             TruthValue,
        tnAmplifierPortAutoReEnableMode                   TruthValue,
--        obsolete
--        tnAmplifierPortAutoReEnableBackoffTime            Unsigned32,
        tnAmplifierPortPowerSpanRepairMargin              Unsigned32,
        tnAmplifierPortPowerDeltaMax                      Unsigned32,
        tnAmplifierPortTargetTilt                         Integer32,
        tnAmplifierPortFunction                           INTEGER,
        tnAmplifierPortAprDisable                         TruthValue,
        tnAmplifierPortSRSTiltACoeffDCM                   Integer32,
        tnAmplifierPortMaxFlatGainOffset                  Integer32,
        tnAmplifierPortGainTilt                           Integer32,
        tnAmplifierPortAprHoldOffTime                     INTEGER,
        tnAmplifierPortLosMode                            INTEGER,
        tnAmplifierPortSignalFailThreshold                Unsigned32,
        tnAmplifierPortSignalDegradeThreshold             Unsigned32,
        tnAmplifierPortVoaSet                             Unsigned32,
        tnAmplifierPortGainRange                          INTEGER,
        tnAmplifierPortAprMode                            INTEGER,
        tnAmplifierPortOperatingMode                      INTEGER,
        tnAmplifierPortSignalPowerTarget                  Integer32,
        tnAmplifierPortPowerGainL                         Unsigned32,
        tnAmplifierPortPowerGainMinL                      Unsigned32,
        tnAmplifierPortPowerGainMaxL                      Unsigned32,
        tnAmplifierPortPowerDeltaMaxL                     Unsigned32,
        tnAmplifierPortGainRangeL                         INTEGER,
        tnAmplifierPortTargetTiltL                        Integer32,
        tnAmplifierPortVoaSetL                            Unsigned32,
        tnAmplifierPortGainTiltL                          Integer32,
        tnAmplifierPortPowerGainBackoffL                  Unsigned32,
        tnAmplifierPortPowerSpanRepairMarginL             Unsigned32,
        tnAmplifierPortOperatingModeL                     INTEGER,
        tnAmplifierPortSignalPowerTargetL                 Integer32,
        tnAmplifierPortUserSelectedExteriorDcmPresentIn   TruthValue,
        tnAmplifierPortUserSelectedExteriorDcmPresentOut  TruthValue,
        tnAmplifierPortBandMode                           INTEGER,
        tnAmplifierPortLosModeL                           INTEGER,
        tnAmplifierPortBoosterTargetPowerIn               Integer32,
        tnAmplifierPortAprEDFApulse                       INTEGER,
        tnAmplifierPortLineDcmConnAddress                 InterfaceIndexOrZero,
        tnAmplifierPortAPREDFAPulseAttempt                TnCommand,
        tnAmplifierPortSpanLossTh                         Integer32,
        tnAmplifierPortAsellLink                          TruthValue,
        tnAmplifierPortTargetPowerWidth                   NokiaAmpPortTargetPowerWidth,
        tnAmplifierPortTargetPowerWidthL                  NokiaAmpPortTargetPowerWidth,
        tnAmplifierPortAsellLinkL                         TruthValue
    }

    tnAmplifierPortPowerGain OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the signal
                        port of the amplifier card:

                        Current configurable ranges and defaults:

                        A2325A:           (1600..3200), 1600
                        A2P2125 (port 1): ( 200..2000), 1000
                        A2P2125 (port 4): (1500..3100), 1500
                        A4PSWG (port 1):  ( 700..2900),  700
                        A4PSWG (port 4):  ( 200..2000), 1000

                        AA2DONW:          (1300..2300), 1300
                        AAR_8A:           (1000..2000), 1500
                        AHPHG:            (1300..3300), 1300
                        AHPLG:            ( 600..2400),  600
                        ALPFGK:           (1300..2300), 1800

                        ALPFGT:           (1300..2300), 1800
                        ALPHG:            (1000..3000), 1000
                        AM2017B:          ( 600..2400),  600
                        AM2032A:          (2600..4000), 2600
                        AM2125A:          (1500..3100), 1500

                        AM2125B:          (1500..3100), 1500
                        AM2318A:          ( 700..2400),  700
                        AM2325B:          (1600..3200), 1600
                        AM2625A:          (1600..3000), 1600
                        ASWG:             ( 700..2900),  700

                        MESH4:            ( 700..2400),  700
                        RA2P:             ( 200..2000), 1000."
        ::= { tnAmplifierPortConfigEntry 1 }

    tnAmplifierPortPowerGainMin OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the signal
                        port of the amplifier card:

                        This value is used by power management.

                        Current configurable ranges and defaults:

                        A2325A:           (1600..3200), 1600
                        A2P2125 (port 1): (   0..2500),  700
                        A2P2125 (port 4): (1500..3100), 1500
                        A4PSWG (port 1):  (   0..2500),  700
                        A4PSWG (port 4):  ( 700..2900),  700

                        AA2DONW:          (1300..2300), 1300
                        AHPHG:            (1300..3300), 1300
                        AHPLG:            ( 600..2400),  600
                        ALPFGK:           (1300..2300), 1300
                        ALPFGT:           (1300..2300), 1300

                        ALPHG:            (1000..3000), 1000
                        AM2017B:          ( 600..2400),  600
                        AM2032A:          (2600..4000), 2600
                        AM2125A:          (1500..3100), 1500
                        AM2125B:          (1500..3100), 1500

                        AM2318A:          ( 700..2400),  700
                        AM2325B:          (1600..3200), 1600
                        AM2625A:          (1600..3000), 1600
                        ASWG:             ( 700..2900),  700
                        MESH4:            ( 700..2400),  700

                        RA2P:             (   0..2500),  700."
        ::= { tnAmplifierPortConfigEntry 2 }

    tnAmplifierPortPowerGainMax OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the signal
                        port of the amplifier card:

                        This value is used by power management.

                        Current configurable ranges and defaults:

                        A2325A:           (1600..3200), 3200
                        A2P2125 (port 1): (   0..2500), 2500
                        A2P2125 (port 4): (1500..3100), 3100
                        A4PSWG (port 1):  (   0..2500), 2500
                        A4PSWG (port 4):  ( 700..2900), 2200

                        AA2DONW:          (1300..2300), 2300
                        AHPHG:            (1300..3300), 3300
                        AHPLG:            ( 600..2400), 2400
                        ALPFGK:           (1300..2300), 2300
                        ALPFGT:           (1300..2300), 2300

                        ALPHG:            (1000..3000), 3000
                        AM2017B:          ( 600..2400), 2400
                        AM2032A:          (2600..4000), 4000
                        AM2125A:          (1500..3100), 3100
                        AM2125B:          (1500..3100), 3100

                        AM2318A:          ( 700..2400), 2400
                        AM2325B:          (1600..3200), 3200
                        AM2625A:          (1600..3000), 3000
                        ASWG:             ( 700..2900), 2200
                        MESH4:            ( 700..2400), 2400

                        RA2P:             (   0..2500), 2500."
        ::= { tnAmplifierPortConfigEntry 3 }

    tnAmplifierPortPowerGainBackoff OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the signal
                        port of the amplifier card:

                        The adjustment made to min/max gain by power
                        management when commissioning.

                        Current configurable range: 0 to 1000."
        DEFVAL         { 0 }
        ::= { tnAmplifierPortConfigEntry 4 }

    tnAmplifierPortEnable OBJECT-TYPE
        SYNTAX         TruthValue
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the signal
                        port of the amplifier card:

                        This attribute allows a network operator to kick
                        start the laser.  Setting a value of false is
                        restricted."
        DEFVAL         { true }
        ::= { tnAmplifierPortConfigEntry 5 }

    tnAmplifierPortAutoReEnableMode OBJECT-TYPE
        SYNTAX         TruthValue
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        ampOutThruIn port of the amplifier card:

                        Auto re-enable mode."
        DEFVAL         { true }
        ::= { tnAmplifierPortConfigEntry 6 }

--    obsolete
--    tnAmplifierPortAutoReEnableBackoffTime OBJECT-TYPE ::= { tnAmplifierPortConfigEntry 7 }

    tnAmplifierPortPowerSpanRepairMargin OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the signal
                        port of the amplifier card:

                        EPT - splice margin.

                        This is calculated as the absolute value of the
                        difference between tnAmplifierPortPowerGainMax
                        and tnAmplifierPortPowerGainBackoff.

                        Current ranges and defaults:

                        ASWG:   (700..2900), 2200
                        A4PSWG: (700..2900), 2200."
        ::= { tnAmplifierPortConfigEntry 8 }

    tnAmplifierPortPowerDeltaMax OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the signal
                        port of the amplifier card:

                        EPT - delta max.

                        Current configurable range: 0 to 500."
        DEFVAL         { 0 }
        ::= { tnAmplifierPortConfigEntry 9 }

    tnAmplifierPortTargetTilt OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the signal
                        port of the amplifier card:

                        EPT - Tilt.

                        Configurable ranges and defaults:

                        A2325A:  (-300..   0),    0
                        A2P2125: (-300.. 300),    0
                        A2P2125: (-400.. 400),    0
                        AHPHG:   (-300..   0),    0
                        AHPLG:   (-300..   0),    0
                        ALPHG:   (-300..   0),    0
                        AM2017B: (-300..   0),    0
                        AM2032A: (-300..   0),    0
                        AM2125A: (-400.. 400),    0
                        AM2125B: (-400.. 400),    0
                        AM2318A: (-400.. 400),    0
                        AM2325B: (-300..   0),    0
                        AM2625A: (-600..-100), -100
                        MESH4:   (-400.. 400),    0
                        RA2P:    (-300.. 300),    0
                        ASWG:    (-400.. 400),    0
                        A4PSWG:  (-400.. 400),    0."
        ::= { tnAmplifierPortConfigEntry 10 }

    tnAmplifierPortFunction OBJECT-TYPE
        SYNTAX         INTEGER {
                         ingress(1),
                         egress(2),
                         other(3)
                       }
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Indicates the functional type of the amplifier
                        card."
        ::= { tnAmplifierPortConfigEntry 11 }

    tnAmplifierPortAprDisable OBJECT-TYPE
        SYNTAX         TruthValue
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The Auto Power Recovery Disable."
        DEFVAL         { false }
        ::= { tnAmplifierPortConfigEntry 12 }

    tnAmplifierPortSRSTiltACoeffDCM OBJECT-TYPE
        SYNTAX         Integer32
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Modeling coefficient for the
                        SRSTilt = A*Pout(mW) equation, for DCM.

                        Current configurable range: 0 to 10000."
        DEFVAL         { 0 }
        ::= { tnAmplifierPortConfigEntry 13 }

    tnAmplifierPortMaxFlatGainOffset OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Provides a correction to the assumed max flat
                        gain value.

                        Current configurable range: -500 to 500."
        DEFVAL         { 0 }
        ::= { tnAmplifierPortConfigEntry 14 }

    tnAmplifierPortGainTilt OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Current OA tilt setting for the signal port of
                        the amplifier card.

                        Current ranges:

                        AM2625A: -600 to -100
                        AM2032A: -300 to 0
                        ASWG:    -400 to 400
                        A4PSWG:  -400 to 400."
        DEFVAL         { 0 }
        ::= { tnAmplifierPortConfigEntry 15 }

    tnAmplifierPortAprHoldOffTime OBJECT-TYPE
        SYNTAX         INTEGER {
                         time0ms(1),
--                         obsolete
--                         time50ms(2),
--                         time100ms(3),
                         time250ms(4)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The auto power recovery hold off time."
        DEFVAL         { time0ms }
        ::= { tnAmplifierPortConfigEntry 16 }

    tnAmplifierPortLosMode OBJECT-TYPE
        SYNTAX         INTEGER {
                         auto(1),
                         losn(2)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The Amplifier Port LOS Mode."
        DEFVAL         { auto }
        ::= { tnAmplifierPortConfigEntry 17 }

    tnAmplifierPortSignalFailThreshold OBJECT-TYPE
        SYNTAX         Unsigned32 (0..12)
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Integer range 4 to 5, representing 10**4 to 10**5.

                        Current configurable range: 4 to 5."
        DEFVAL         { 4 }
        ::= { tnAmplifierPortConfigEntry 18 }

    tnAmplifierPortSignalDegradeThreshold OBJECT-TYPE
        SYNTAX         Unsigned32 (0..12)
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Integer range 5 to 9, representing 10**5 to 10**9.

                        Current configurable range: 5 to 9."
        DEFVAL         { 6 }
        ::= { tnAmplifierPortConfigEntry 19 }

    tnAmplifierPortVoaSet OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mBm"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        LINEOUT port of the uni-directionalamplifier
                        card:

                        Current configurable range: 0 to 1800."
        DEFVAL         { 0 }
        ::= { tnAmplifierPortConfigEntry 20 }

    tnAmplifierPortGainRange OBJECT-TYPE
        SYNTAX         INTEGER {
                         low(1),
                         high(2)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Gain range for ASWG/A4PSWG cards."
        DEFVAL         { low }
        ::= { tnAmplifierPortConfigEntry 21 }

    tnAmplifierPortAprMode OBJECT-TYPE
        SYNTAX         INTEGER {
                         auto(1),
                         force(2)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "APR Mode for ASWG/A4PSWG cards."
        DEFVAL         { auto }
        ::= { tnAmplifierPortConfigEntry 22 }

    tnAmplifierPortOperatingMode OBJECT-TYPE
        SYNTAX         INTEGER {
                         gain(1),
                         power(2),
                         maxPower(3)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "ASE Mode for ASWG/A4PSWG cards.

                         Set to power (node sets LD to LOSN as well)
                         Set to gain (node sets LD to LOSA as well)."
        DEFVAL         { gain }
        ::= { tnAmplifierPortConfigEntry 23 }

    tnAmplifierPortSignalPowerTarget OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Value used when tnAmplifierPortOperatingMode
                        is in power mode.

                        Current configurable range: -400 to 1000."
        DEFVAL         { 300 }
        ::= { tnAmplifierPortConfigEntry 24 }

    tnAmplifierPortPowerGainL OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Specifies the amplifier gain."

        ::= { tnAmplifierPortConfigEntry 25 }

    tnAmplifierPortPowerGainMinL OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Specifies the minimum EDFA gain."

        ::= { tnAmplifierPortConfigEntry 26 }

    tnAmplifierPortPowerGainMaxL OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Specifies the maximum EDFA gain."

        ::= { tnAmplifierPortConfigEntry  27}

    tnAmplifierPortPowerDeltaMaxL OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Specifies the maximum allowed difference between the
                        provisioned gain and the measured gain before an
                        alarm is raised."

        DEFVAL         { 0 }
        ::= { tnAmplifierPortConfigEntry 28 }

    tnAmplifierPortGainRangeL OBJECT-TYPE
        SYNTAX         INTEGER {
                         low(1),
                         high(2)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Specifies the EDFA gain range.."
        DEFVAL         { low }
        ::= { tnAmplifierPortConfigEntry 29 }

    tnAmplifierPortTargetTiltL OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Specifies the amplifier tilt value used by the system."

        ::= { tnAmplifierPortConfigEntry 30 }

    tnAmplifierPortVoaSetL OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mBm"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Specifies the output VOA setting."
        DEFVAL         { 0 }
        ::= { tnAmplifierPortConfigEntry 31 }

    tnAmplifierPortGainTiltL OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Current OA tilt setting for the signal port of
                        the amplifier card for L band."
        DEFVAL         { 0 }
        ::= { tnAmplifierPortConfigEntry 32 }

    tnAmplifierPortPowerGainBackoffL OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the signal
                        port of the amplifier card for L band:

                        The adjustment made to min/max gain by power
                        management when commissioning.

                        Current configurable range: 0 to 1000."
        DEFVAL         { 0 }
        ::= { tnAmplifierPortConfigEntry 33 }

    tnAmplifierPortPowerSpanRepairMarginL OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the signal
                        port of the amplifier card for L Band:

                        EPT - splice margin.

                        This is calculated as the absolute value of the
                        difference between tnAmplifierPortPowerGainMaxL
                        and tnAmplifierPortPowerGainBackoffL."
        ::= { tnAmplifierPortConfigEntry 34 }

    tnAmplifierPortOperatingModeL OBJECT-TYPE
        SYNTAX         INTEGER {
                         gain(1),
                         power(2),
                         maxPower(3)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "ASE Mode for ASWG/A4PSWG cards for L-Band.

                         Set to power (node sets LD to LOSN as well)
                         Set to gain (node sets LD to LOSA as well)."
        DEFVAL         { gain }
        ::= { tnAmplifierPortConfigEntry 35 }

    tnAmplifierPortSignalPowerTargetL OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Value used when tnAmplifierPortOperatingModeL
                        is in power mode for L-Band.

                        Current configurable range: -400 to 1000."
        DEFVAL         { 300 }
        ::= { tnAmplifierPortConfigEntry 36 }

    tnAmplifierPortUserSelectedExteriorDcmPresentIn OBJECT-TYPE
        SYNTAX         TruthValue
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Manage external DCM."
        DEFVAL         { false }
        ::= { tnAmplifierPortConfigEntry 37 }

    tnAmplifierPortUserSelectedExteriorDcmPresentOut OBJECT-TYPE
        SYNTAX         TruthValue
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Manage external DCM."
        DEFVAL         { false }
        ::= { tnAmplifierPortConfigEntry 38 }

    tnAmplifierPortBandMode OBJECT-TYPE
        SYNTAX         INTEGER {
                          cBand(1),
                          lBand(2),
                          clBand(3)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "This attribute determines if the LD is operating
                        in a single or dual band. If in a single  band mode,
                        only the  provisioned band attributes are made availabe
                        to provision and retrieve."
        DEFVAL         { clBand }
        ::= { tnAmplifierPortConfigEntry 39 }

    tnAmplifierPortLosModeL OBJECT-TYPE
        SYNTAX         INTEGER {
                         auto(1),
                         losn(2)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The Amplifier Port LOS Mode in L band."
        DEFVAL         { auto }
        ::= { tnAmplifierPortConfigEntry 40 }

    tnAmplifierPortBoosterTargetPowerIn OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Target Power Per Channel.

                        Current configurable range: -500 to 600."
        DEFVAL         { -100 }
        ::= { tnAmplifierPortConfigEntry 41 }

    tnAmplifierPortAprEDFApulse OBJECT-TYPE
        SYNTAX         INTEGER {
                         on(1),
                         off(2)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "APR EDFA Pulsing."
        DEFVAL         { on }
        ::= { tnAmplifierPortConfigEntry 42 }

    tnAmplifierPortLineDcmConnAddress OBJECT-TYPE
        SYNTAX         InterfaceIndexOrZero
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierPortConfigEntry 43 }

    tnAmplifierPortAPREDFAPulseAttempt OBJECT-TYPE
        SYNTAX         TnCommand
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "APR pulse attempt."
        DEFVAL         { noCmd }
        ::= { tnAmplifierPortConfigEntry 44 }

    tnAmplifierPortSpanLossTh OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Span loss threshold ."
        DEFVAL         { -9900 }
        ::= { tnAmplifierPortConfigEntry 45 }

    tnAmplifierPortAsellLink OBJECT-TYPE
        SYNTAX         TruthValue
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "."
        DEFVAL         { false }
        ::= { tnAmplifierPortConfigEntry 46 }

    tnAmplifierPortTargetPowerWidth OBJECT-TYPE
        SYNTAX         NokiaAmpPortTargetPowerWidth
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "."
        DEFVAL         { channelWidth50GHz }
        ::= { tnAmplifierPortConfigEntry 47 }

    tnAmplifierPortTargetPowerWidthL OBJECT-TYPE
        SYNTAX         NokiaAmpPortTargetPowerWidth
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "."
        DEFVAL         { channelWidth50GHz }
        ::= { tnAmplifierPortConfigEntry 48 }

    tnAmplifierPortAsellLinkL OBJECT-TYPE
        SYNTAX         TruthValue
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "."
        DEFVAL         { false }
        ::= { tnAmplifierPortConfigEntry 49 }

--------------------------------------------------------------------------------
-- Hybrid Amplifier Port Config Scalars
--------------------------------------------------------------------------------
    tnAmplifierHybridPortConfigAttributeTotal OBJECT-TYPE
        SYNTAX         Integer32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Total number of attributes in
                        tnAmplifierHybridPortConfigTable."
        ::= { tnAmplifierPortConfig 3 }

--------------------------------------------------------------------------------
-- Hybrid Amplifier Port Config Table
--------------------------------------------------------------------------------
    tnAmplifierHybridPortConfigTable OBJECT-TYPE
        SYNTAX         SEQUENCE OF TnAmplifierHybridPortConfigEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "The provisioned ports on an hybrid amplifier
                        card."
        ::= { tnAmplifierPortConfig 4 }

    tnAmplifierHybridPortConfigEntry OBJECT-TYPE
        SYNTAX         TnAmplifierHybridPortConfigEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "."
        INDEX { ifIndex }
        ::= { tnAmplifierHybridPortConfigTable 1 }

    TnAmplifierHybridPortConfigEntry ::= SEQUENCE {
        tnAmplifierHybridPortVoaAttenuation           Unsigned32,
        tnAmplifierHybridPortInitialMidLoss           Unsigned32,
        tnAmplifierHybridPortInitialAgcTargetGain     Unsigned32,
        tnAmplifierHybridPortVoaMinAttenuation        Unsigned32,
        tnAmplifierHybridPortVoaMaxAttenuation        Unsigned32
    }

    tnAmplifierHybridPortVoaAttenuation OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Hybrid amplifier port VOA attenuation.

                        Current configurable range: 0 to 2000."
        DEFVAL         { 0 }
        ::= { tnAmplifierHybridPortConfigEntry 1 }

    tnAmplifierHybridPortInitialMidLoss OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Hybrid amplifier port initial VOA attenuation.

                        Current configurable range: 0 to 2000."
        DEFVAL         { 60 }
        ::= { tnAmplifierHybridPortConfigEntry 2 }

    tnAmplifierHybridPortInitialAgcTargetGain OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Hybrid amplifier port initial AGC target gain.

                        Current configurable range: 200 to 2000."
        DEFVAL         { 1000 }
        ::= { tnAmplifierHybridPortConfigEntry 3 }

    tnAmplifierHybridPortVoaMinAttenuation OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Hybrid amplifier port VOA minimum attenuation.

                        Current configurable range: 0 to 2000."
        DEFVAL         { 0 }
        ::= { tnAmplifierHybridPortConfigEntry 4 }

    tnAmplifierHybridPortVoaMaxAttenuation OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Hybrid amplifier port VOA maximum attenuation.

                        Current configurable range: 0 to 2000."
        DEFVAL         { 2000 }
        ::= { tnAmplifierHybridPortConfigEntry 5 }

--------------------------------------------------------------------------------
-- Amplifier Port Info Scalars
--------------------------------------------------------------------------------
    tnAmplifierPortInfoAttributeTotal OBJECT-TYPE
        SYNTAX         Integer32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Total number of attributes in
                        tnAmplifierPortInfoTable."
        ::= { tnAmplifierPortInfo 1 }

--------------------------------------------------------------------------------
-- Amplifier Port Info Table
--------------------------------------------------------------------------------
    tnAmplifierPortInfoTable OBJECT-TYPE
        SYNTAX         SEQUENCE OF TnAmplifierPortInfoEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "The equipped ports on an amplifier card."
        ::= { tnAmplifierPortInfo 2 }

    tnAmplifierPortInfoEntry OBJECT-TYPE
        SYNTAX         TnAmplifierPortInfoEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "."
        INDEX { ifIndex }
        ::= { tnAmplifierPortInfoTable 1 }

    TnAmplifierPortInfoEntry ::= SEQUENCE {
        tnAmplifierPortInternalAmpModuleTemperature  Integer32,
        tnAmplifierPortPowerIn                       Integer32,
        tnAmplifierPortPowerOut                      Integer32,
        tnAmplifierPortSignalPowerOut                Integer32,
        tnAmplifierPortInputToOutputGain             Integer32,
        tnAmplifierPortDCMInPower                    Integer32,
        tnAmplifierPortDCMOutPower                   Integer32,
        tnAmplifierPortActualTilt                    Integer32,
        tnAmplifierPortWtOcmMonitorPortOut           Unsigned32,
        tnAmplifierPortOSCTxPowerIn                  Integer32,
        tnAmplifierPortOSCTxPowerOut                 Integer32,
        tnAmplifierPortTestingActive                 TruthValue,
        tnAmplifierCommonEgressOutputPower           Integer32,
        tnAmplifierActOutAtten                       Unsigned32,
        tnAmplifierCommonEgressOutputPowerL          Integer32,
        tnAmplifierActOutAttenL                      Unsigned32,
        tnAmplifierPortActualTiltL                   Integer32,
        tnAmplifierPortSignalPowerOutL               Integer32,
        tnAmplifierPortInputToOutputGainL            Integer32,
        tnAmplifierPortOSCTxPowerOutL                Integer32,
        tnAmplifierPortPowerInL                      Integer32,
        tnAmplifierPortInfoOSCRxPowerIn              Integer32,
        tnAmplifierPortInfoOSCSfpTxPowerOut          Integer32,
        tnAmplifierPortInfoOSCSfpRxPowerIn           Integer32,
        tnAmplifierPortBoosterTargetPowerOut         Integer32,
        tnAmplifierPortPowerOutL                     Integer32,
        tnAmplifierPortSpanLoss                      Integer32,
        tnAmplifierPortAprEDFApulsePower             Unsigned32
    }

    tnAmplifierPortInternalAmpModuleTemperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        signal port of the amplifier card:

                        The temperature of the laser.

                        Current range:  -5 to 35."
        DEFVAL         { 30 }
        ::= { tnAmplifierPortInfoEntry 1 }

    tnAmplifierPortPowerIn OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        fromDcm and line ports of the amplifier card:

                        The total input power
                        Current ranges:
                        ASWG:   -9900, -3600 to 1700
                        A4PSWG: -9900, -3600 to 1700."
        ::= { tnAmplifierPortInfoEntry 2 }

    tnAmplifierPortPowerOut OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        signal and toDcm ports of the amplifier card:

                        The total output power.

                        Current ranges:

                        AM2625A: -9900, -900 to 2900
                        AM2032A: -9900, -300 to 2300
                        ASWG:    -9900, -1100 to 2550
                        A4PSWG:  -9900, -1100 to 2550."
        ::= { tnAmplifierPortInfoEntry 3 }

    tnAmplifierPortSignalPowerOut OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        signal port of the amplifier card:

                        The total input power plus the programmed gain.

                        Current Ranges:
                        ASWG:    -9900, -1100 to 2550
                        A4PSWG:  -9900, -1100 to 2550."
        ::= { tnAmplifierPortInfoEntry 4 }

    tnAmplifierPortInputToOutputGain OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        LINEOUT port of the uni-directional amplifier
                        card.
                        Current Ranges:
                        ASWG:    -9900, -300 to 2900
                        A4PSWG:  -9900, -300 to 2900."
        ::= { tnAmplifierPortInfoEntry 5 }

    tnAmplifierPortDCMInPower OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the DCM
                        In port of the amplifier card.  -9900 indicates
                        no measured power.

                        Current range: -9900, -3000 to 2000."
        DEFVAL         { -9900 }
        ::= { tnAmplifierPortInfoEntry 6 }

    tnAmplifierPortDCMOutPower OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the DCM
                        Out port of the amplifier card.  -9900 indicates
                        no measured power.

                        Current range: -9900, -3000 to 2000."
        DEFVAL         { -9900 }
        ::= { tnAmplifierPortInfoEntry 7 }

    tnAmplifierPortActualTilt OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        signal port of the amplifier card:

                        Current range: -1000 to 500."
        ::= { tnAmplifierPortInfoEntry 8 }

    tnAmplifierPortWtOcmMonitorPortOut OBJECT-TYPE
        SYNTAX         Unsigned32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The associated WTOCM In port associated to the LD.

                        Current range: 0 to 0xFFFFFFFF."
        DEFVAL         { 0 }
        ::= { tnAmplifierPortInfoEntry 9 }

    tnAmplifierPortOSCTxPowerIn OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The EDFA module OSC transmitted input power of
                        the amplifier card.  -9900 indicates no measured
                        power.

                        Current ranges:

                        A2P2125:  -1500 to 1100
                        AM2032A:  -1500 to 1100
                        AM2125A:  -1500 to 1100
                        AM2125B:  -1500 to 1100
                        AM2318A:  -1500 to 1100
                        AM2625A:  -2000 to 1100
                        ASWG:     -1500 to 1100
                        A4PSWG:   -1500 to 1100."
        DEFVAL         { -9900 }
        ::= { tnAmplifierPortInfoEntry 10 }

    tnAmplifierPortOSCTxPowerOut OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The EDFA module OSC transmitted output power of
                        the amplifier card.  -9900 indicates no measured
                        power.

                        Current ranges:

                        A2P2125:  -1500 to 1100
                        AA2DONW:  -1500 to 1500
                        AM2032A:  -1500 to 1100
                        AM2125A:  -1500 to 1100
                        AM2125B:  -1500 to 1100
                        AM2318A:  -1500 to 1100
                        AM2625A:      0 to 1500
                        ASWG:     -1500 to 1100
                        A4PSWG:   -1500 to 1100."
        DEFVAL         { -9900 }
        ::= { tnAmplifierPortInfoEntry 11 }

    tnAmplifierPortTestingActive OBJECT-TYPE
        SYNTAX         TruthValue
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Node sets to true when testing in progress
                        on port (logic)."
        DEFVAL         { false }
        ::= { tnAmplifierPortInfoEntry 12 }

    tnAmplifierCommonEgressOutputPower OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Calculated in scot when tiltadj is triggered.Referes to the
                        Target output power per channel,adjusted for the C+L Interaction."
        ::= { tnAmplifierPortInfoEntry 13 }

    tnAmplifierActOutAtten OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Actual amplifier attenuation available on the AWBxx packs only."
        DEFVAL         { 0 }
        ::= { tnAmplifierPortInfoEntry 14 }

    tnAmplifierCommonEgressOutputPowerL OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Calculated in scot when tiltadj is triggered.Referes to the
                        Target output power per channel,adjusted for the C+L Interaction."
        ::= { tnAmplifierPortInfoEntry 15 }

    tnAmplifierActOutAttenL OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Actual amplifier attenuation available on the AWBxx packs only
                        for L Band."
        DEFVAL         { 0 }
        ::= { tnAmplifierPortInfoEntry 16 }

    tnAmplifierPortActualTiltL OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        signal port of the amplifier card for L band:

                        Current range: -1000 to 500."
        ::= { tnAmplifierPortInfoEntry 17 }

    tnAmplifierPortSignalPowerOutL OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        signal port of the amplifier card for L band:

                        The total input power plus the programmed gain."
        ::= { tnAmplifierPortInfoEntry 18 }

    tnAmplifierPortInputToOutputGainL OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        LINEOUT port of the uni-directional amplifier
                        card for L band."
        ::= { tnAmplifierPortInfoEntry 19 }

    tnAmplifierPortOSCTxPowerOutL OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The EDFA module OSC transmitted output power of
                        the amplifier card.  -9900 indicates no measured
                        power."
        DEFVAL         { -9900 }
        ::= { tnAmplifierPortInfoEntry 20 }

    tnAmplifierPortPowerInL OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "EDFA module total input power L band."
        ::= { tnAmplifierPortInfoEntry 21 }

    tnAmplifierPortInfoOSCRxPowerIn OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The EDFA module OSC received input power to the card.
                        -9900 indicates no measured power."
        ::= { tnAmplifierPortInfoEntry 22 }

    tnAmplifierPortInfoOSCSfpTxPowerOut OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The OSCSFP transceiver output power -9900 indicates
                        no measured power."
        ::= { tnAmplifierPortInfoEntry 23 }

    tnAmplifierPortInfoOSCSfpRxPowerIn OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The OSCSFP transceiver input power -9900 indicates no
                        measured power."
        ::= { tnAmplifierPortInfoEntry 24 }

    tnAmplifierPortBoosterTargetPowerOut OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Target Power Per Channel."
        ::= { tnAmplifierPortInfoEntry 25 }

    tnAmplifierPortPowerOutL OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Total output power for L Band."
        ::= { tnAmplifierPortInfoEntry 26 }

    tnAmplifierPortSpanLoss OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Span loss."
        DEFVAL         { 9900 }
        ::= { tnAmplifierPortInfoEntry 27 }

    tnAmplifierPortAprEDFApulsePower OBJECT-TYPE
        SYNTAX         Unsigned32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Apr EDFA pulse Power."
        ::= { tnAmplifierPortInfoEntry 28 }

--------------------------------------------------------------------------------
-- Amplifier MESH Port Info Scalars
--------------------------------------------------------------------------------
    tnAmplifierMeshPortInfoAttributeTotal OBJECT-TYPE
        SYNTAX         Integer32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Total number of attributes in
                        tnAmplifierMeshPortInfoTable."
        ::= { tnAmplifierPortInfo 3 }

--------------------------------------------------------------------------------
-- Amplifier Mesh Port Info Table
--------------------------------------------------------------------------------
    tnAmplifierMeshPortInfoTable OBJECT-TYPE
        SYNTAX         SEQUENCE OF TnAmplifierMeshPortInfoEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "The equipped ports on a mesh card."
        ::= { tnAmplifierPortInfo 4 }

    tnAmplifierMeshPortInfoEntry OBJECT-TYPE
        SYNTAX         TnAmplifierMeshPortInfoEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "."
        INDEX { ifIndex }
        ::= { tnAmplifierMeshPortInfoTable 1 }

    TnAmplifierMeshPortInfoEntry ::=
        SEQUENCE {
            tnAmplifierMeshPortPowerOut            Integer32,
            tnAmplifierMeshPortSignalPowerOut      Integer32,
            tnAmplifierMeshPortInputToOutputGain   Integer32
        }

    tnAmplifierMeshPortPowerOut OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the output
                        port of the mesh card:

                        The total output power.

                        -9900 indicates no measured power."
        DEFVAL         { -9900 }
        ::= { tnAmplifierMeshPortInfoEntry 1 }

    tnAmplifierMeshPortSignalPowerOut OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        output port of the mesh card:

                        The total input power plus the programmed gain.

                        -9900 indicates no measured power."
        DEFVAL         { -9900 }
        ::= { tnAmplifierMeshPortInfoEntry 2 }

    tnAmplifierMeshPortInputToOutputGain OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description reports the gain from
                        sigIn to sigOut ports of the MESH4 card:

                        OA module gain - EVOA loss - SEEPROM loss of
                        splitter.

                        Current range:

                        MESH4: -1100 to 2400."
        DEFVAL         { 700 }
        ::= { tnAmplifierMeshPortInfoEntry 3 }

--------------------------------------------------------------------------------
-- Hybrid Amplifier Port Info Scalars
--------------------------------------------------------------------------------
    tnAmplifierHybridPortInfoAttributeTotal OBJECT-TYPE
        SYNTAX         Integer32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Total number of attributes in
                        tnAmplifierHybridPortInfoTable."
        ::= { tnAmplifierPortInfo 5 }

--------------------------------------------------------------------------------
-- Hybrid Amplifier Port Info Table
--------------------------------------------------------------------------------
    tnAmplifierHybridPortInfoTable OBJECT-TYPE
        SYNTAX         SEQUENCE OF TnAmplifierHybridPortInfoEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "The equipped ports on an hybrid amplifier card."
        ::= { tnAmplifierPortInfo 6 }

    tnAmplifierHybridPortInfoEntry OBJECT-TYPE
        SYNTAX         TnAmplifierHybridPortInfoEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "."
        INDEX { ifIndex }
        ::= { tnAmplifierHybridPortInfoTable 1 }

    TnAmplifierHybridPortInfoEntry ::= SEQUENCE {
        tnAmplifierHybridPortInternalAmpModuleTemperature     Unsigned32
    }

    tnAmplifierHybridPortInternalAmpModuleTemperature OBJECT-TYPE
        SYNTAX         Unsigned32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Hybrid Amplifier Port Internal Module Temperature."
        ::= { tnAmplifierHybridPortInfoEntry 1 }

--------------------------------------------------------------------------------
-- Amplifier Card Info Scalars
--------------------------------------------------------------------------------
    tnAmplifierCardInfoAttributeTotal OBJECT-TYPE
        SYNTAX         Integer32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Total number of attributes in
                        tnAmplifierCardInfoTable."
        ::= { tnAmplifierCardInfo 1 }

--------------------------------------------------------------------------------
-- Amplifier Card Info Table
--------------------------------------------------------------------------------
    tnAmplifierCardInfoTable OBJECT-TYPE
        SYNTAX         SEQUENCE OF TnAmplifierCardInfoEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "The equipped pumps and other values on an
                        amplifier card."
        ::= { tnAmplifierCardInfo 2 }

    tnAmplifierCardInfoEntry OBJECT-TYPE
        SYNTAX         TnAmplifierCardInfoEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "."
        INDEX { tnShelfIndex,
                tnSlotIndex }
        ::= { tnAmplifierCardInfoTable 1 }

    TnAmplifierCardInfoEntry ::= SEQUENCE {
        tnAmplifierCardOAMPump1Temperature      Integer32,
        tnAmplifierCardOAMPump2Temperature      Integer32,
        tnAmplifierCardOAMPump3Temperature      Integer32,
        tnAmplifierCardOAMPump1Bias             Integer32,
        tnAmplifierCardOAMPump2Bias             Integer32,
        tnAmplifierCardOAMPump3Bias             Integer32,
        tnAmplifierCardOptIntSpanLoss           Integer32,
        tnAmplifierCardOAMPump4Temperature      Integer32,
        tnAmplifierCardOAMPump5Temperature      Integer32,
        tnAmplifierCardOAMPump6Temperature      Integer32,
        tnAmplifierCardOAMPump4Bias             Integer32,
        tnAmplifierCardOAMPump5Bias             Integer32,
        tnAmplifierCardOAMPump6Bias             Integer32,
        tnAmplifierCardOAMLPump1Temperature     Integer32,
        tnAmplifierCardOAMLPump2Temperature     Integer32,
        tnAmplifierCardOAMLPump3Temperature     Integer32,
        tnAmplifierCardOAMLPump4Temperature     Integer32,
        tnAmplifierCardOAMLPump1Bias            Integer32,
        tnAmplifierCardOAMLPump2Bias            Integer32,
        tnAmplifierCardOAMLPump3Bias            Integer32,
        tnAmplifierCardOAMLPump4Bias            Integer32,
        tnAmplifierCardOAM1PumpTemperatures     SnmpAdminString,
        tnAmplifierCardOAM2PumpTemperatures     SnmpAdminString,
        tnAmplifierCardOAM1PumpBiases           SnmpAdminString,
        tnAmplifierCardOAM2PumpBiases           SnmpAdminString,
        tnAmplifierCardOAM3PumpTemperatures     SnmpAdminString,
        tnAmplifierCardOAM3PumpBiases           SnmpAdminString,
        tnAmplifierCardOAM1LPumpTemperatures    SnmpAdminString,
        tnAmplifierCardOAM2LPumpTemperatures    SnmpAdminString,
        tnAmplifierCardOAM3LPumpTemperatures    SnmpAdminString,
        tnAmplifierCardOAM1LPumpBiases          SnmpAdminString,
        tnAmplifierCardOAM2LPumpBiases          SnmpAdminString,
        tnAmplifierCardOAM3LPumpBiases          SnmpAdminString
     }

    tnAmplifierCardOAMPump1Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 1."
        ::= { tnAmplifierCardInfoEntry 1 }

    tnAmplifierCardOAMPump2Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 2."
        ::= { tnAmplifierCardInfoEntry 2 }

    tnAmplifierCardOAMPump3Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 3."
        ::= { tnAmplifierCardInfoEntry 3 }

    tnAmplifierCardOAMPump1Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 1."
        ::= { tnAmplifierCardInfoEntry 4 }

    tnAmplifierCardOAMPump2Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 2."
        ::= { tnAmplifierCardInfoEntry 5 }

    tnAmplifierCardOAMPump3Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 3."
        ::= { tnAmplifierCardInfoEntry 6 }

    tnAmplifierCardOptIntSpanLoss OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The span loss value.

                        Current range: 0 to 9900."
        DEFVAL         { 9900 }
        ::= { tnAmplifierCardInfoEntry 7 }

    tnAmplifierCardOAMPump4Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 4."
        ::= { tnAmplifierCardInfoEntry 8 }

    tnAmplifierCardOAMPump5Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 5."
        ::= { tnAmplifierCardInfoEntry 9 }

    tnAmplifierCardOAMPump6Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 6."
        ::= { tnAmplifierCardInfoEntry 10 }

    tnAmplifierCardOAMPump4Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 4."
        ::= { tnAmplifierCardInfoEntry 11 }

    tnAmplifierCardOAMPump5Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 5."
        ::= { tnAmplifierCardInfoEntry 12 }

    tnAmplifierCardOAMPump6Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 6."
        ::= { tnAmplifierCardInfoEntry 13 }

    tnAmplifierCardOAMLPump1Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 1 for L Band."
        ::= { tnAmplifierCardInfoEntry 14 }

    tnAmplifierCardOAMLPump2Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 2 for L Band."
        ::= { tnAmplifierCardInfoEntry 15 }

    tnAmplifierCardOAMLPump3Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 3 for L Band."
        ::= { tnAmplifierCardInfoEntry 16 }

    tnAmplifierCardOAMLPump4Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 4 for L Band."
        ::= { tnAmplifierCardInfoEntry 17 }

    tnAmplifierCardOAMLPump1Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 1 for L Band."
        ::= { tnAmplifierCardInfoEntry 18 }

    tnAmplifierCardOAMLPump2Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 2 for L Band."
        ::= { tnAmplifierCardInfoEntry 19 }

    tnAmplifierCardOAMLPump3Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 3 for L Band."
        ::= { tnAmplifierCardInfoEntry 20 }

    tnAmplifierCardOAMLPump4Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 4 for L Band."
        ::= { tnAmplifierCardInfoEntry 21 }

    tnAmplifierCardOAM1PumpTemperatures OBJECT-TYPE
        SYNTAX         SnmpAdminString (SIZE(0..512))
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "String containing number of pumps for the 1st optical
                        amplifier on the card, followed by the pump temperature
                        for each pump.  For IROADM9R OAM1 is the ingress OA module."
        ::= { tnAmplifierCardInfoEntry 22 }

        tnAmplifierCardOAM2PumpTemperatures OBJECT-TYPE
        SYNTAX         SnmpAdminString (SIZE(0..512))
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "String containing number of pumps for the 2nd OA module
                        on the card, followed by the pump temperature for each
                        pump.  For IROADM9R OAM2 is the egress OA module."
        ::= { tnAmplifierCardInfoEntry 23 }

    tnAmplifierCardOAM1PumpBiases OBJECT-TYPE
        SYNTAX         SnmpAdminString (SIZE(0..512))
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "String containing number of pumps for the 1st optical
                        amplifier on the card, followed by the pump bias current
                        for each pump.  For IROADM9R OAM1 is the ingress OA module."
        ::= { tnAmplifierCardInfoEntry 24 }

    tnAmplifierCardOAM2PumpBiases OBJECT-TYPE
        SYNTAX         SnmpAdminString (SIZE(0..512))
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "String containing number of pumps for the 2nd optical
                        amplifier on the card, followed by the pump bias current
                        for each pump.  For IROADM9R OAM2 is the egress OA module."
        ::= { tnAmplifierCardInfoEntry 25 }

    tnAmplifierCardOAM3PumpTemperatures OBJECT-TYPE
        SYNTAX         SnmpAdminString (SIZE(0..512))
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "String containing number of pumps for the 3rd OA module
                        on the card, followed by the pump temperature for each
                        pump."
        ::= { tnAmplifierCardInfoEntry 26 }

    tnAmplifierCardOAM3PumpBiases OBJECT-TYPE
        SYNTAX         SnmpAdminString (SIZE(0..512))
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "String containing number of pumps for the 3rd optical
                        amplifier on the card, followed by the pump bias current
                        for each pump."
        ::= { tnAmplifierCardInfoEntry 27 }

    tnAmplifierCardOAM1LPumpTemperatures OBJECT-TYPE
        SYNTAX         SnmpAdminString (SIZE(0..512))
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardInfoEntry 28 }

    tnAmplifierCardOAM2LPumpTemperatures OBJECT-TYPE
        SYNTAX         SnmpAdminString (SIZE(0..512))
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardInfoEntry 29 }

    tnAmplifierCardOAM3LPumpTemperatures OBJECT-TYPE
        SYNTAX         SnmpAdminString (SIZE(0..512))
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardInfoEntry 30 }

    tnAmplifierCardOAM1LPumpBiases OBJECT-TYPE
        SYNTAX         SnmpAdminString (SIZE(0..512))
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardInfoEntry 31 }

    tnAmplifierCardOAM2LPumpBiases OBJECT-TYPE
        SYNTAX         SnmpAdminString (SIZE(0..512))
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardInfoEntry 32 }

    tnAmplifierCardOAM3LPumpBiases OBJECT-TYPE
        SYNTAX         SnmpAdminString (SIZE(0..512))
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardInfoEntry 33 }

--------------------------------------------------------------------------------
-- Mesh Amplifier Card Info Scalars
--------------------------------------------------------------------------------
    tnAmplifierMeshCardInfoAttributeTotal OBJECT-TYPE
        SYNTAX         Integer32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Total number of attributes in
                        tnAmplifierMeshCardInfoTable."
        ::= { tnAmplifierCardInfo 3 }

--------------------------------------------------------------------------------
-- Mesh Amplifier Card Info Table
--------------------------------------------------------------------------------
    tnAmplifierMeshCardInfoTable OBJECT-TYPE
        SYNTAX         SEQUENCE OF TnAmplifierMeshCardInfoEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "The measured values on an amplifier module in
                        a mesh card."
        ::= { tnAmplifierCardInfo 4 }

    tnAmplifierMeshCardInfoEntry OBJECT-TYPE
        SYNTAX         TnAmplifierMeshCardInfoEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "."
        INDEX { tnShelfIndex,
                tnSlotIndex }
        ::= { tnAmplifierMeshCardInfoTable 1 }

    TnAmplifierMeshCardInfoEntry ::= SEQUENCE {
        tnAmplifierMeshCardInternalTemperature   Integer32,
        tnAmplifierMeshCardPowerIn               Integer32,
        tnAmplifierMeshCardPowerOut              Integer32,
        tnAmplifierMeshCardSignalPowerOut        Integer32,
        tnAmplifierMeshCardInputToOutputGain     Integer32,
        tnAmplifierMeshCardGainTilt              Integer32,
        tnAmplifierMeshCardActualTilt            Integer32
    }

    tnAmplifierMeshCardInternalTemperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the
                        amplifier module in the mesh card:

                        The temperature of the laser.

                        Current range:

                        MESH4:  -5 to 35."
        DEFVAL         { 30 }
        ::= { tnAmplifierMeshCardInfoEntry 1 }

    tnAmplifierMeshCardPowerIn OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the input
                        port of the amplifier module in the mesh card:

                        The total input power.

                        -9900 indicates no measured power."
        ::= { tnAmplifierMeshCardInfoEntry 2 }

    tnAmplifierMeshCardPowerOut OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the output
                        port of the amplifier module in the mesh card:

                        The total output power.

                        -9900 indicates no measured power."
        ::= { tnAmplifierMeshCardInfoEntry 3 }

    tnAmplifierMeshCardSignalPowerOut OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the output
                        port of the amplifier module in the mesh card:

                        The total input power plus the programmed gain.

                        -9900 indicates no measured power."
        ::= { tnAmplifierMeshCardInfoEntry 4 }

    tnAmplifierMeshCardInputToOutputGain OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the output
                        port of the amplifier module in the mesh card:

                        Current range:

                        MESH4: -1100 to 2400."
        DEFVAL         { 700 }
        ::= { tnAmplifierMeshCardInfoEntry 5 }

    tnAmplifierMeshCardGainTilt OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Current OA tilt setting for the output port of
                        the amplifier module in the mesh card."
        ::= { tnAmplifierMeshCardInfoEntry 6 }

    tnAmplifierMeshCardActualTilt OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mB"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The following description applies to the output
                        port of the amplifier module in the mesh card:

                        Current range:

                        MESH4: -1000 to 500."
        ::= { tnAmplifierMeshCardInfoEntry 7 }

--------------------------------------------------------------------------------
-- Hybrid Amplifier Card Info Scalars
--------------------------------------------------------------------------------
    tnAmplifierHybridCardInfoAttributeTotal OBJECT-TYPE
        SYNTAX         Integer32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Total number of attributes in
                        tnAmplifierHybridCardInfoTable."
        ::= { tnAmplifierCardInfo 5 }

--------------------------------------------------------------------------------
-- Hybrid Amplifier Card Info Table
--------------------------------------------------------------------------------
    tnAmplifierHybridCardInfoTable OBJECT-TYPE
        SYNTAX         SEQUENCE OF TnAmplifierHybridCardInfoEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "The measured values on an amplifier module in
                        a mesh card."
        ::= { tnAmplifierCardInfo 6 }

    tnAmplifierHybridCardInfoEntry OBJECT-TYPE
        SYNTAX         TnAmplifierHybridCardInfoEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "."
        INDEX { tnShelfIndex,
                tnSlotIndex }
        ::= { tnAmplifierHybridCardInfoTable 1 }

    TnAmplifierHybridCardInfoEntry ::= SEQUENCE {
        tnAmplifierHybridCardOAMPump1Temperature     Integer32,
        tnAmplifierHybridCardOAMPump2Temperature     Integer32,
        tnAmplifierHybridCardOAMPump1Bias            Integer32,
        tnAmplifierHybridCardOAMPump2Bias            Integer32,
        tnAmplifierHybridCardOAMPump3Temperature     Integer32,
        tnAmplifierHybridCardOAMPump4Temperature     Integer32,
        tnAmplifierHybridCardOAMPump3Bias            Integer32,
        tnAmplifierHybridCardOAMPump4Bias            Integer32
    }

    tnAmplifierHybridCardOAMPump1Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 1."
        ::= { tnAmplifierHybridCardInfoEntry 1 }

    tnAmplifierHybridCardOAMPump2Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 2."
        ::= { tnAmplifierHybridCardInfoEntry 2 }

    tnAmplifierHybridCardOAMPump1Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 1."
        DEFVAL         { 0 }
        ::= { tnAmplifierHybridCardInfoEntry 3 }

    tnAmplifierHybridCardOAMPump2Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 2."
        DEFVAL         { 0 }
        ::= { tnAmplifierHybridCardInfoEntry 4 }

    tnAmplifierHybridCardOAMPump3Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 3."
        ::= { tnAmplifierHybridCardInfoEntry 5 }

    tnAmplifierHybridCardOAMPump4Temperature OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "Celsius"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current temperature of the OA Laser Pump 4."
        ::= { tnAmplifierHybridCardInfoEntry 6 }

    tnAmplifierHybridCardOAMPump3Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 3."
        DEFVAL         { 0 }
        ::= { tnAmplifierHybridCardInfoEntry 7 }

    tnAmplifierHybridCardOAMPump4Bias OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mA"
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "The current bias of the OA Laser Pump 4."
        DEFVAL         { 0 }
        ::= { tnAmplifierHybridCardInfoEntry 8 }

--------------------------------------------------------------------------------
-- Amplifier Card Config Scalars
--------------------------------------------------------------------------------
    tnAmplifierCardConfigAttributeTotal OBJECT-TYPE
        SYNTAX         Integer32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Total number of attributes in
                        tnAmplifierCardConfigTable."
        ::= { tnAmplifierCardConfig 1 }

--------------------------------------------------------------------------------
-- Amplifier Card Config Table
--------------------------------------------------------------------------------
    tnAmplifierCardConfigTable OBJECT-TYPE
        SYNTAX         SEQUENCE OF TnAmplifierCardConfigEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "The configurable values on an amplifier card."
        ::= { tnAmplifierCardConfig 2 }

    tnAmplifierCardConfigEntry OBJECT-TYPE
        SYNTAX         TnAmplifierCardConfigEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "."
        INDEX { tnShelfIndex,
                tnSlotIndex }
        ::= { tnAmplifierCardConfigTable 1 }

    TnAmplifierCardConfigEntry ::= SEQUENCE {
        tnAmplifierCardOptIntDetection                INTEGER,
        tnAmplifierCardOptIntBaseline                 Integer32,
        tnAmplifierCardOptIntLossThreshold            Integer32,
        tnAmplifierCardOptIntPollPeriod               Integer32,
        tnAmplifierCardOptIntClearAlarm               TnCommand,
        tnAmplifierCardAsonAddDropPlannedForOps       TruthValue,
        tnAmplifierCardUsage                          INTEGER,
        tnAmplifierCardAsonAddDropPlannedForOpsLBand  TruthValue,
        tnAmplifierCardOptIntAson                     INTEGER
     }

    tnAmplifierCardOptIntDetection OBJECT-TYPE
        SYNTAX         INTEGER {
                         on(1),
                         off(2)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The status of the Optical Intrusion detection
                        feature."
        DEFVAL         { off }
        ::= { tnAmplifierCardConfigEntry 1 }

    tnAmplifierCardOptIntBaseline OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The optical intrusion baseline value, with -100
                        means no value has been set.

                        Current configurable range: -100, 100 to 5000."
        DEFVAL         { -100 }
        ::= { tnAmplifierCardConfigEntry 2 }

    tnAmplifierCardOptIntLossThreshold OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "mBm"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The optical intrusion loss threshold value.

                        Current configurable range: 100 to 500."
        DEFVAL         { 150 }
        ::= { tnAmplifierCardConfigEntry 3 }

    tnAmplifierCardOptIntPollPeriod OBJECT-TYPE
        SYNTAX         Integer32
        UNITS          "seconds"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The optical intrusion poll period.

                        Current configurable range: 20 to 120."
        DEFVAL         { 30 }
        ::= { tnAmplifierCardConfigEntry 4 }

    tnAmplifierCardOptIntClearAlarm OBJECT-TYPE
        SYNTAX         TnCommand
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Clears optical intrusion alarm."
        DEFVAL         { noCmd }
        ::= { tnAmplifierCardConfigEntry 5 }

    tnAmplifierCardAsonAddDropPlannedForOps OBJECT-TYPE
        SYNTAX         TruthValue
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Used for ASON nodes running GMRE.  The value
                        indicates if an LD defining the add/drop block
                        has been planned to accept OPSA OCH protected
                        services."
        DEFVAL         { false }
        ::= { tnAmplifierCardConfigEntry 6 }

    tnAmplifierCardUsage OBJECT-TYPE
        SYNTAX         INTEGER {
                         line(1),
                         standAlone(2),
                         addDrop(3)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "."
        DEFVAL         { line }
        ::= { tnAmplifierCardConfigEntry 7 }

    tnAmplifierCardAsonAddDropPlannedForOpsLBand OBJECT-TYPE
        SYNTAX         TruthValue
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "L Band. Used for ASON nodes running GMRE.  The value
                        indicates if an LD defining the add/drop block has
                        been planned to accept OPSA OCH protected services."
        DEFVAL         { false }
        ::= { tnAmplifierCardConfigEntry 8 }

    tnAmplifierCardOptIntAson OBJECT-TYPE
        SYNTAX         INTEGER {
                         on(1),
                         off(2)
                       }
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Enables or disables ason monitoring of the optical
                        instrusion monitoring.
                        on  - enables ASON monitoring
                        off - disables ASON monitoring."
        DEFVAL         { on }
        ::= { tnAmplifierCardConfigEntry 9 }

--------------------------------------------------------------------------------
-- Mesh Amplifier Card Config Scalars
--------------------------------------------------------------------------------
    tnAmplifierMeshCardConfigAttributeTotal OBJECT-TYPE
        SYNTAX         Integer32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION    "Total number of attributes in
                        tnAmplifierMeshCardConfigTable."
        ::= { tnAmplifierCardConfig 3 }

--------------------------------------------------------------------------------
-- Mesh Amplifier Card Config Table
--------------------------------------------------------------------------------
    tnAmplifierMeshCardConfigTable OBJECT-TYPE
        SYNTAX         SEQUENCE OF TnAmplifierMeshCardConfigEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "The provisioned parameters on an amplifier
                        module in a mesh card."
        ::= { tnAmplifierCardConfig 4 }

    tnAmplifierMeshCardConfigEntry OBJECT-TYPE
        SYNTAX         TnAmplifierMeshCardConfigEntry
        MAX-ACCESS     not-accessible
        STATUS         current
        DESCRIPTION    "."
        INDEX { tnShelfIndex,
                tnSlotIndex }
        ::= { tnAmplifierMeshCardConfigTable 1 }

    TnAmplifierMeshCardConfigEntry ::= SEQUENCE {
        tnAmplifierMeshCardPowerGain           Unsigned32,
        tnAmplifierMeshCardPowerGainMin        Unsigned32,
        tnAmplifierMeshCardPowerGainMax        Unsigned32,
        tnAmplifierMeshCardTargetTilt          Integer32,
        tnAmplifierMeshCardVoaSet              Unsigned32,
        tnAmplifierMeshCardCommonEgressPower   Integer32
    }

    tnAmplifierMeshCardPowerGain OBJECT-TYPE
        SYNTAX         Unsigned32 (700..2400)
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the output
                        port of the amplifier module in the mesh card:

                        Current configurable range:

                        MESH4:  700 to 2400."
        DEFVAL         { 700 }
        ::= { tnAmplifierMeshCardConfigEntry 1 }

    tnAmplifierMeshCardPowerGainMin OBJECT-TYPE
        SYNTAX         Unsigned32 (700..2400)
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the output
                        port of the amplifier module in the mesh card:

                        This value is used by power management.

                        Current configurable range:

                        MESH4:  700 to 2400."
        DEFVAL         { 700 }
        ::= { tnAmplifierMeshCardConfigEntry 2 }

    tnAmplifierMeshCardPowerGainMax OBJECT-TYPE
        SYNTAX         Unsigned32 (700..2400)
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the output
                        port of the amplifier module in the mesh card:

                        This value is used by power management.

                        Current configurable range:

                        MESH4:  700 to 2400."
        DEFVAL         { 2400 }
        ::= { tnAmplifierMeshCardConfigEntry 3 }

    tnAmplifierMeshCardTargetTilt OBJECT-TYPE
        SYNTAX         Integer32 (-400..400)
        UNITS          "mB"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the output
                        port of the amplifier module in the mesh card:

                        EPT - Tilt.

                        Current configurable range:

                        MESH4:  -400 to 400."
        DEFVAL         { 0 }
        ::= { tnAmplifierMeshCardConfigEntry 4 }

    tnAmplifierMeshCardVoaSet OBJECT-TYPE
        SYNTAX         Unsigned32 (0..1800)
        UNITS          "mBm"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "The following description applies to the output
                        port of the amplifier module in the mesh card:

                        Current configurable range:

                        MESH4:  0 to 1800."
        DEFVAL         { 0 }
        ::= { tnAmplifierMeshCardConfigEntry 5 }

    tnAmplifierMeshCardCommonEgressPower OBJECT-TYPE
        SYNTAX         Integer32 (-1000..1000)
        UNITS          "mBm"
        MAX-ACCESS     read-create
        STATUS         current
        DESCRIPTION    "Common Egress Power.  This is the per channel
                        default egress power

                        Current configurable range:

                        MESH4: -1000 to 1000."
        DEFVAL         { 100 }
        ::= { tnAmplifierMeshCardConfigEntry 6 }

--------------------------------------------------------------------------------
-- Conformance Group Definitions
--------------------------------------------------------------------------------

--------------------------------------------------------------------------------
-- Conformance Amplifier Port Config Group Definitions
--------------------------------------------------------------------------------
    tnAmplifierPortConfigScalarsGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierPortConfigAttributeTotal
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierPortConfigGroups 1 }

    tnAmplifierPortConfigGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierPortPowerGain,
            tnAmplifierPortPowerGainMin,
            tnAmplifierPortPowerGainMax,
            tnAmplifierPortPowerGainBackoff,
            tnAmplifierPortEnable,
            tnAmplifierPortAutoReEnableMode,
--            obsolete
--            tnAmplifierPortAutoReEnableBackoffTime,
            tnAmplifierPortPowerSpanRepairMargin,
            tnAmplifierPortPowerDeltaMax,
            tnAmplifierPortTargetTilt,
            tnAmplifierPortFunction,
            tnAmplifierPortAprDisable,
            tnAmplifierPortSRSTiltACoeffDCM,
            tnAmplifierPortMaxFlatGainOffset,
            tnAmplifierPortGainTilt,
            tnAmplifierPortAprHoldOffTime,
            tnAmplifierPortLosMode,
            tnAmplifierPortSignalFailThreshold,
            tnAmplifierPortSignalDegradeThreshold,
            tnAmplifierPortVoaSet,
            tnAmplifierPortGainRange,
            tnAmplifierPortAprMode,
            tnAmplifierPortOperatingMode,
            tnAmplifierPortSignalPowerTarget,
            tnAmplifierPortPowerGainL,
            tnAmplifierPortPowerGainMinL,
            tnAmplifierPortPowerGainMaxL,
            tnAmplifierPortPowerDeltaMaxL,
            tnAmplifierPortGainRangeL,
            tnAmplifierPortTargetTiltL,
            tnAmplifierPortVoaSetL,
            tnAmplifierPortGainTiltL,
            tnAmplifierPortPowerGainBackoffL,
            tnAmplifierPortPowerSpanRepairMarginL,
            tnAmplifierPortOperatingModeL,
            tnAmplifierPortSignalPowerTargetL,
            tnAmplifierPortUserSelectedExteriorDcmPresentIn,
            tnAmplifierPortUserSelectedExteriorDcmPresentOut,
            tnAmplifierPortBandMode,
            tnAmplifierPortLosModeL,
            tnAmplifierPortBoosterTargetPowerIn,
            tnAmplifierPortAprEDFApulse,
            tnAmplifierPortLineDcmConnAddress,
            tnAmplifierPortAPREDFAPulseAttempt,
            tnAmplifierPortSpanLossTh,
            tnAmplifierPortAsellLink,
            tnAmplifierPortTargetPowerWidth,
            tnAmplifierPortTargetPowerWidthL,
            tnAmplifierPortAsellLinkL
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierPortConfigGroups 2 }

    tnAmplifierHybridPortConfigScalarsGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierHybridPortConfigAttributeTotal
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierPortConfigGroups 3 }

    tnAmplifierHybridPortConfigGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierHybridPortVoaAttenuation,
            tnAmplifierHybridPortInitialMidLoss,
            tnAmplifierHybridPortInitialAgcTargetGain,
            tnAmplifierHybridPortVoaMinAttenuation,
            tnAmplifierHybridPortVoaMaxAttenuation
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierPortConfigGroups 4 }

--------------------------------------------------------------------------------
-- Conformance Amplifier Port Info Group Definitions
--------------------------------------------------------------------------------
    tnAmplifierPortInfoScalarsGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierPortInfoAttributeTotal
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierPortInfoGroups 1 }

    tnAmplifierPortInfoGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierPortInternalAmpModuleTemperature,
            tnAmplifierPortPowerIn,
            tnAmplifierPortPowerOut,
            tnAmplifierPortSignalPowerOut,
            tnAmplifierPortInputToOutputGain,
            tnAmplifierPortDCMInPower,
            tnAmplifierPortDCMOutPower,
            tnAmplifierPortActualTilt,
            tnAmplifierPortWtOcmMonitorPortOut,
            tnAmplifierPortOSCTxPowerIn,
            tnAmplifierPortOSCTxPowerOut,
            tnAmplifierPortTestingActive,
            tnAmplifierCommonEgressOutputPower,
            tnAmplifierActOutAtten,
            tnAmplifierCommonEgressOutputPowerL,
            tnAmplifierActOutAttenL,
            tnAmplifierPortActualTiltL,
            tnAmplifierPortSignalPowerOutL,
            tnAmplifierPortInputToOutputGainL,
            tnAmplifierPortOSCTxPowerOutL,
            tnAmplifierPortPowerInL,
            tnAmplifierPortInfoOSCRxPowerIn,
            tnAmplifierPortInfoOSCSfpTxPowerOut,
            tnAmplifierPortInfoOSCSfpRxPowerIn,
            tnAmplifierPortBoosterTargetPowerOut,
            tnAmplifierPortPowerOutL,
            tnAmplifierPortSpanLoss,
            tnAmplifierPortAprEDFApulsePower
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierPortInfoGroups 2 }

    tnAmplifierMeshPortInfoScalarsGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierMeshPortInfoAttributeTotal
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierPortInfoGroups 3 }

    tnAmplifierMeshPortInfoGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierMeshPortPowerOut,
            tnAmplifierMeshPortSignalPowerOut,
            tnAmplifierMeshPortInputToOutputGain
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierPortInfoGroups 4 }

    tnAmplifierHybridPortInfoScalarsGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierHybridPortInfoAttributeTotal
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierPortInfoGroups 5 }

    tnAmplifierHybridPortInfoGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierHybridPortInternalAmpModuleTemperature
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierPortInfoGroups 6 }

--------------------------------------------------------------------------------
-- Conformance Amplifier Card Info Group Definitions
--------------------------------------------------------------------------------
    tnAmplifierCardInfoScalarsGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierCardInfoAttributeTotal
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardInfoGroups 1 }

    tnAmplifierCardInfoGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierCardOAMPump1Temperature,
            tnAmplifierCardOAMPump2Temperature,
            tnAmplifierCardOAMPump3Temperature,
            tnAmplifierCardOAMPump1Bias,
            tnAmplifierCardOAMPump2Bias,
            tnAmplifierCardOAMPump3Bias,
            tnAmplifierCardOptIntSpanLoss,
            tnAmplifierCardOAMPump4Temperature,
            tnAmplifierCardOAMPump5Temperature,
            tnAmplifierCardOAMPump6Temperature,
            tnAmplifierCardOAMPump4Bias,
            tnAmplifierCardOAMPump5Bias,
            tnAmplifierCardOAMPump6Bias,
            tnAmplifierCardOAMLPump1Temperature,
            tnAmplifierCardOAMLPump2Temperature,
            tnAmplifierCardOAMLPump3Temperature,
            tnAmplifierCardOAMLPump4Temperature,
            tnAmplifierCardOAMLPump1Bias,
            tnAmplifierCardOAMLPump2Bias,
            tnAmplifierCardOAMLPump3Bias,
            tnAmplifierCardOAMLPump4Bias,
            tnAmplifierCardOAM1PumpTemperatures,
            tnAmplifierCardOAM2PumpTemperatures,
            tnAmplifierCardOAM1PumpBiases,
            tnAmplifierCardOAM2PumpBiases,
            tnAmplifierCardOAM3PumpTemperatures,
            tnAmplifierCardOAM3PumpBiases,
            tnAmplifierCardOAM1LPumpTemperatures,
            tnAmplifierCardOAM2LPumpTemperatures,
            tnAmplifierCardOAM3LPumpTemperatures,
            tnAmplifierCardOAM1LPumpBiases,
            tnAmplifierCardOAM2LPumpBiases,
            tnAmplifierCardOAM3LPumpBiases
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardInfoGroups 2 }

    tnAmplifierMeshCardInfoScalarsGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierMeshCardInfoAttributeTotal
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardInfoGroups 3 }

    tnAmplifierMeshCardInfoGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierMeshCardInternalTemperature,
            tnAmplifierMeshCardPowerIn,
            tnAmplifierMeshCardPowerOut,
            tnAmplifierMeshCardSignalPowerOut,
            tnAmplifierMeshCardInputToOutputGain,
            tnAmplifierMeshCardGainTilt,
            tnAmplifierMeshCardActualTilt
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardInfoGroups 4 }

    tnAmplifierHybridCardInfoScalarsGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierHybridCardInfoAttributeTotal
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardInfoGroups 5 }

    tnAmplifierHybridCardInfoGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierHybridCardOAMPump1Temperature,
            tnAmplifierHybridCardOAMPump2Temperature,
            tnAmplifierHybridCardOAMPump1Bias,
            tnAmplifierHybridCardOAMPump2Bias,
            tnAmplifierHybridCardOAMPump3Temperature,
            tnAmplifierHybridCardOAMPump4Temperature,
            tnAmplifierHybridCardOAMPump3Bias,
            tnAmplifierHybridCardOAMPump4Bias
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardInfoGroups 6 }

--------------------------------------------------------------------------------
-- Conformance Amplifier Card Config Group Definitions
--------------------------------------------------------------------------------
    tnAmplifierCardConfigScalarsGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierCardConfigAttributeTotal
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardConfigGroups 1 }

    tnAmplifierCardConfigGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierCardOptIntDetection,
            tnAmplifierCardOptIntBaseline,
            tnAmplifierCardOptIntLossThreshold,
            tnAmplifierCardOptIntPollPeriod,
            tnAmplifierCardOptIntClearAlarm,
            tnAmplifierCardAsonAddDropPlannedForOps,
            tnAmplifierCardUsage,
            tnAmplifierCardAsonAddDropPlannedForOpsLBand,
            tnAmplifierCardOptIntAson
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardConfigGroups 2 }

    tnAmplifierMeshCardConfigScalarsGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierMeshCardConfigAttributeTotal
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardConfigGroups 3 }

    tnAmplifierMeshCardConfigGroup OBJECT-GROUP
        OBJECTS {
            tnAmplifierMeshCardPowerGain,
            tnAmplifierMeshCardPowerGainMin,
            tnAmplifierMeshCardPowerGainMax,
            tnAmplifierMeshCardTargetTilt,
            tnAmplifierMeshCardVoaSet,
            tnAmplifierMeshCardCommonEgressPower
        }
        STATUS         current
        DESCRIPTION    "."
        ::= { tnAmplifierCardConfigGroups 4 }

--------------------------------------------------------------------------------
-- Compliance Statements (mandatory)
--------------------------------------------------------------------------------

--------------------------------------------------------------------------------
-- Compliance Port Config Statements (mandatory)
--------------------------------------------------------------------------------
    tnAmplifierPortConfigCompliance MODULE-COMPLIANCE
        STATUS         current
        DESCRIPTION    "."
        MODULE
        MANDATORY-GROUPS  {
            tnAmplifierPortConfigScalarsGroup,
            tnAmplifierPortConfigGroup,
            tnAmplifierHybridPortConfigScalarsGroup,
            tnAmplifierHybridPortConfigGroup
        }
        ::= { tnAmplifierPortConfigCompliances 1 }

--------------------------------------------------------------------------------
-- Compliance Port Info Statements (mandatory)
--------------------------------------------------------------------------------
    tnAmplifierPortInfoCompliance MODULE-COMPLIANCE
        STATUS         current
        DESCRIPTION    "."
        MODULE
        MANDATORY-GROUPS  {
            tnAmplifierPortInfoScalarsGroup,
            tnAmplifierPortInfoGroup,
            tnAmplifierMeshPortInfoScalarsGroup,
            tnAmplifierMeshPortInfoGroup,
            tnAmplifierHybridPortInfoScalarsGroup,
            tnAmplifierHybridPortInfoGroup
        }
        ::= { tnAmplifierPortInfoCompliances 1 }

--------------------------------------------------------------------------------
-- Compliance Card Info Statements (mandatory)
--------------------------------------------------------------------------------
    tnAmplifierCardInfoCompliance MODULE-COMPLIANCE
        STATUS         current
        DESCRIPTION    "."
        MODULE
        MANDATORY-GROUPS  {
            tnAmplifierCardInfoScalarsGroup,
            tnAmplifierCardInfoGroup,
            tnAmplifierMeshCardInfoScalarsGroup,
            tnAmplifierMeshCardInfoGroup,
            tnAmplifierHybridCardInfoScalarsGroup,
            tnAmplifierHybridCardInfoGroup
        }
        ::= { tnAmplifierCardInfoCompliances 1 }

--------------------------------------------------------------------------------
-- Compliance Card Config Statements (mandatory)
--------------------------------------------------------------------------------
    tnAmplifierCardConfigCompliance MODULE-COMPLIANCE
        STATUS         current
        DESCRIPTION    "."
        MODULE
        MANDATORY-GROUPS  {
            tnAmplifierCardConfigScalarsGroup,
            tnAmplifierCardConfigGroup,
            tnAmplifierMeshCardConfigScalarsGroup,
            tnAmplifierMeshCardConfigGroup
        }
        ::= { tnAmplifierCardConfigCompliances 1 }

END -- DEFINITION OF TROPIC-AMPLIFIER-MIB